Factors That Impact the Duration of MRI-Guided Core Needle Biopsy
Mitra Noroozian, Eva C. Gombos, Sona Chikarmane, Dianne Georgian-Smith, Sughra Raza, Christine M. Denison, Elisabeth P. Frost, and Robyn L. Birdwell
AJR 2010;194:150-157
Link to Journal
Variables that minimized procedure duration were number of image acquisitions, number of patient insertions or removals from the magnet, and assistance of a breast imaging fellow-in-training. No patient-related or target-related variables impacted procedure time
Thursday, 21 January 2010
Comparison of Acquisition Parameters and Breast Dose in Digital Mammography and Screen-Film Mammography in the American College of Radiology Imaging N
Comparison of Acquisition Parameters and Breast Dose in Digital Mammography and Screen-Film Mammography in the American College of Radiology Imaging Network Digital Mammographic Imaging Screening Trial
R. Edward Hendrick, Etta D. Pisano, Alice Averbukh, Catherine Moran, Eric A. Berns, Martin J. Yaffe, Benjamin Herman, Suddhasatta Acharyya, and Constantine Gatsonis
AJR 2010;194:362-369
Link to Journal
Differences between screen-film mammography and FFDM in compression force and indicated compressed breast thickness were small. On average, FFDM had 22% lower mean glandular dose than screen-film mammography per acquired view, with sizeable variations in average FFDM doses by manufacturer
R. Edward Hendrick, Etta D. Pisano, Alice Averbukh, Catherine Moran, Eric A. Berns, Martin J. Yaffe, Benjamin Herman, Suddhasatta Acharyya, and Constantine Gatsonis
AJR 2010;194:362-369
Link to Journal
Differences between screen-film mammography and FFDM in compression force and indicated compressed breast thickness were small. On average, FFDM had 22% lower mean glandular dose than screen-film mammography per acquired view, with sizeable variations in average FFDM doses by manufacturer
Labels:
ACRIN,
breast thickness,
compression force,
DMIST
MR-Directed ("Second-Look") Ultrasound Examination for Breast Lesions Detected Initially on MRI: MR and Sonographic Findings
MR-Directed ("Second-Look") Ultrasound Examination for Breast Lesions Detected Initially on MRI: MR and Sonographic Findings
Hiroyuki Abe, Robert A. Schmidt, Rajshri N. Shah, Akiko Shimauchi, Kirti Kulkarni, Charlene A. Sennett, and Gillian M. Newstead
AJR 2010;194:370-377
Link to Journal
MR-directed ultrasound of MRI-detected lesions was useful for decision making as part of the diagnostic workup. Malignant lesions were likely to have an ultrasound correlate, especially when they presented as masses on MRI. However, the sonographic findings of these lesions were often subtle, and careful scanning technique was needed for successful MRI–ultrasound correlation
(Ed..) this validates studies from Korea and Italy, published in Europe which showed that an US correlate was strongly associated with subsequent outcome of malignancy
Hiroyuki Abe, Robert A. Schmidt, Rajshri N. Shah, Akiko Shimauchi, Kirti Kulkarni, Charlene A. Sennett, and Gillian M. Newstead
AJR 2010;194:370-377
Link to Journal
MR-directed ultrasound of MRI-detected lesions was useful for decision making as part of the diagnostic workup. Malignant lesions were likely to have an ultrasound correlate, especially when they presented as masses on MRI. However, the sonographic findings of these lesions were often subtle, and careful scanning technique was needed for successful MRI–ultrasound correlation
(Ed..) this validates studies from Korea and Italy, published in Europe which showed that an US correlate was strongly associated with subsequent outcome of malignancy
Solitary Dilated Duct Identified at Mammography: Outcomes Analysis
Solitary Dilated Duct Identified at Mammography: Outcomes Analysis
C. Belinda Chang, Natalya M. Lvoff, Jessica W. Leung, R. James Brenner, Bonnie N. Joe, Hilda H. Tso, and Edward A. Sickles
AJR 2010;194:378-382
Link to Journal
UCSF PAPER:
Solitary dilated duct is a rare mammographic finding, this series being the largest reported to date. Although few cases are studied, solitary dilated duct appears to have a greater than 2% likelihood of malignancy, sufficiently high to suggest that a suspicious (BI-RADS 4a) assessment may be appropriate
Ed... currently this is in the BIRADS lexicon as a benign finding. Our data suggest otherwise, but we await validation in a follow up series
C. Belinda Chang, Natalya M. Lvoff, Jessica W. Leung, R. James Brenner, Bonnie N. Joe, Hilda H. Tso, and Edward A. Sickles
AJR 2010;194:378-382
Link to Journal
UCSF PAPER:
Solitary dilated duct is a rare mammographic finding, this series being the largest reported to date. Although few cases are studied, solitary dilated duct appears to have a greater than 2% likelihood of malignancy, sufficiently high to suggest that a suspicious (BI-RADS 4a) assessment may be appropriate
Ed... currently this is in the BIRADS lexicon as a benign finding. Our data suggest otherwise, but we await validation in a follow up series
Tuesday, 22 December 2009
Lesion Size Inaccuracies in Digital Mammography
Lesion Size Inaccuracies in Digital Mammography
Jean R. Paquelet and R. Edward Hendrick
AJR 2010;194:115-118
Link to Journal
We show that some combinations of digital mammography acquisition and display systems can lead to clinically significant over- or underestimation of lesion size in magnification mode. This phenomenon can occur even with acquisition and display systems from the same manufacturer. Thus, the accuracy of lesion size in each magnification mode should be a routine QC acceptance test performed on each digital mammography acquisition–display system combination
Jean R. Paquelet and R. Edward Hendrick
AJR 2010;194:115-118
Link to Journal
We show that some combinations of digital mammography acquisition and display systems can lead to clinically significant over- or underestimation of lesion size in magnification mode. This phenomenon can occur even with acquisition and display systems from the same manufacturer. Thus, the accuracy of lesion size in each magnification mode should be a routine QC acceptance test performed on each digital mammography acquisition–display system combination
Labels:
digital mammography,
measurement error,
QC test
Friday, 20 November 2009
Optimal Timing of Breast MRI Examinations for Premenopausal Women Who Do Not Have a Normal Menstrual Cycle
Optimal Timing of Breast MRI Examinations for Premenopausal Women Who Do Not Have a Normal Menstrual Cycle
Richard L. Ellis
AJR 2009;193:1738-1740
Link to Journal
Serum progesterone concentrations corresponding to the follicular phase of a normal menstrual cycle can aid in optimal scheduling of breast MRI examinations for premenopausal women who lack cyclical menses
Richard L. Ellis
AJR 2009;193:1738-1740
Link to Journal
Serum progesterone concentrations corresponding to the follicular phase of a normal menstrual cycle can aid in optimal scheduling of breast MRI examinations for premenopausal women who lack cyclical menses
Labels:
breast MRI,
menstrual cycle,
timing of scan
Preoperative Sonographic Classification of Axillary Lymph Nodes in Patients With Breast Cancer: Node-to-Node Correlation With Surgical Histology and
Preoperative Sonographic Classification of Axillary Lymph Nodes in Patients With Breast Cancer: Node-to-Node Correlation With Surgical Histology and Sentinel Node Biopsy Results
Nariya Cho, Woo Kyung Moon, Wonshik Han, In Ae Park, Jihyoung Cho, and Dong-Young Noh
AJR 2009;193:1731-1737
Link to Journal
Sonographic classification of axillary lymph nodes is effective for predicting the presence of metastases to avoid sentinel node biopsy or to reduce unsuccessful lymphatic mapping during sentinel node biopsy
Nariya Cho, Woo Kyung Moon, Wonshik Han, In Ae Park, Jihyoung Cho, and Dong-Young Noh
AJR 2009;193:1731-1737
Link to Journal
Sonographic classification of axillary lymph nodes is effective for predicting the presence of metastases to avoid sentinel node biopsy or to reduce unsuccessful lymphatic mapping during sentinel node biopsy
Subscribe to:
Posts (Atom)
